Discrete input number |
8 |
Discrete input type |
DI7, DI8 programmable as pulse input 0…30 kHz, 24 V DC <= 30 V) |
Discrete input logic |
16 preset speeds |
Discrete output number |
0 |
Discrete output type |
Relay outputs R1A, R1B, R1C 250 V AC 3000 mA
Relay outputs R1A, R1B, R1C 30 V DC 3000 mA
Relay outputs R2A, R2C 250 V AC 5000 mA
Relay outputs R2A, R2C 30 V DC 5000 mA
Relay outputs R3A, R3C 250 V AC 5000 mA
Relay outputs R3A, R3C 30 V DC 5000 mA |
Analogue input number |
3 |
Analogue input type |
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits
AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits
AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits |
Analogue output number |
2 |
Analogue output type |
Software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits
Software-configurable current AQ1, AQ2 0...20 mA 10 bits
Software-configurable current DQ-, DQ+ 30 V DC
Software-configurable current DQ-, DQ+ 100 mA |
Relay output number |
3 |
Relay output type |
Configurable relay logic R1 fault relay NO/NC 100000 cycles
Configurable relay logic R2 sequence relay NO 100000 cycles
Configurable relay logic R3 sequence relay NO 100000 cycles |
Maximum switching current |
Relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC
Relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC
Relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC
Relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC |
Minimum switching current |
Relay output R1, R2, R3 5 mA 24 V DC |
Phase |
3 phase |
Physical interface |
Ethernet
2-wire RS 485 |
Method of access |
Slave Modbus TCP |
Transmission Rate |
10, 100 Mbits
4800 bps, 9600 bps, 19200 bps, 38.4 Kbps |
Transmission frame |
RTU |
Output voltage |
<= power supply voltage |
Permissible temporary current boost |
1.1 x In 60 s normal duty)
1.5 x In 60 s heavy duty) |
Data format |
8 bits, configurable odd, even or no parity |
Type of polarization |
No impedance |
Frequency resolution |
Display unit 0.1 Hz
Analog input 0.012/50 Hz |
Electrical connection |
Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16
Line side screw terminal 25...50 mm² AWG 4...AWG 1
Motor screw terminal 25...50 mm² AWG 4...AWG 1 |
Connector type |
RJ45 on the remote graphic terminal)Ethernet/Modbus TCP
RJ45 on the remote graphic terminal)Modbus serial |
Exchange mode |
Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP |
Number of addresses |
1…247 Modbus serial |
Supply |
External supply for digital inputs 24 V DC 19…30 V), <1.25 mA overload and short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection
Internal supply for digital inputs and STO 24 V DC 21…27 V), <200 mA overload and short-circuit protection |
Local signalling |
for local diagnostic 3 LEDs
for embedded communication status 3 LEDs (dual colour)
for communication module status 4 LEDs (dual colour)
for presence of voltage 1 LED (red) |
Input compatibility |
DI1...DI6 discrete input level 1 PLC IEC 61131-2
DI5, DI6 discrete input level 1 PLC IEC 65A-68
STOA, STOB discrete input level 1 PLC IEC 61131-2 |
Discrete input logic |
Positive logic (source) DI1...DI8), < 5 V, > 11 V
Negative logic (sink) DI1...DI8), > 16 V, < 10 V |
Sampling duration |
2 ms +/- 0.5 ms DI1...DI4) - discrete input
5 ms +/- 1 ms DI5, DI6) - discrete input
5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input
10 ms +/- 1 ms AO1) - analog output |
Accuracy |
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AO1, AO2 for a temperature variation 60 °C analog output |
Linearity error |
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input
AO1, AO2 +/- 0.2 % analog output |
Refresh time |
Relay output R1, R2, R3)5 ms +/- 0.5 ms) |
Isolation |
Between power and control terminals |
Variable speed drive application selection |
Building - HVAC compressor centrifugal
Food and beverage processing other application
Mining mineral and metal fan
Mining mineral and metal pump
Oil and gas fan
Water and waste water other application
Building - HVAC screw compressor
Food and beverage processing pump
Food and beverage processing fan
Food and beverage processing atomization
Oil and gas electro submersible pump (ESP)
Oil and gas water injection pump
Oil and gas jet fuel pump
Oil and gas compressor for refinery
Water and waste water centrifuge pump
Water and waste water positive displacement pump
Water and waste water electro submersible pump (ESP)
Water and waste water screw pump
Water and waste water lobe compressor
Water and waste water screw compressor
Water and waste water compressor centrifugal
Water and waste water fan
Water and waste water conveyor
Water and waste water mixer |
Motor power range AC-3 |
15…25 kW 200…240 V 3 phase |
Enclosure mounting |
Wall mounted |
4 quadrant operation possible |
False |
Asynchronous motor control profile |
Variable torque standard
Constant torque standard
Optimized torque mode |
Synchronous motor control profile |
Permanent magnet motor
Synchronous reluctance motor |
Maximum output frequency |
500 kHz |
Acceleration and deceleration ramps |
Linear adjustable separately from 0.01...9999 s |
Motor slip compensation |
Can be suppressed
Automatic whatever the load
Not available in permanent magnet motor law
Adjustable |
Switching frequency |
2...12 kHz adjustable
4...12 kHz with derating factor |
Nominal switching frequency |
4 kHz |
Braking to standstill |
By DC injection |
Brake chopper integrated |
False |
Maximum Input Current per Phase |
52.6 A |
Maximum output voltage |
240.0 V |
Apparent power |
18.9 kVA 240 V normal duty)
14.3 kVA 240 V heavy duty) |
Maximum transient current |
69.7 A 60 s normal duty)
70.2 A 60 s heavy duty) |
Network Frequency |
50-60 Hz |
Prospective line Isc |
50 kA |
Base load current at high overload |
46.8 A |
Base load current at low overload |
63.4 A |
Power dissipation in W |
Natural convection 87 W 200 V 4 kHz
Forced convection 486 W 200 V 4 kHz |
With safety function Safely Limited Speed (SLS) |
False |
With safety function Safe brake management (SBC/SBT) |
False |
With safety function Safe Operating Stop (SOS) |
False |
With safety function Safe Position (SP) |
False |
With safety function Safe programmable logic |
False |
With safety function Safe Speed Monitor (SSM) |
False |
With safety function Safe Stop 1 (SS1) |
False |
With sft fct Safe Stop 2 (SS2) |
False |
With safety function Safe torque off (STO) |
True |
With safety function Safely Limited Position (SLP) |
False |
With safety function Safe Direction (SDI) |
False |
Protection type |
Thermal protection motor
Safe torque off motor
Motor phase break motor
Thermal protection drive
Safe torque off drive
Overheating drive
Overcurrent between output phases and earth drive
Overload of output voltage drive
Short-circuit protection drive
Motor phase break drive
Overvoltages on the DC bus drive
Line supply overvoltage drive
Line supply undervoltage drive
Line supply phase loss drive
Overspeed drive
Break on the control circuit drive |
Quantity per Set |
1 |
Width |
8.9 in (226 mm) |
Height |
26.5 in (673 mm) |
Depth |
10.7 in (271 mm) |
Net Weight |
30.0 lb(US) (13.6 kg) |